KYMATA-AMP-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
    Integer32, IpAddress, enterprises
        FROM SNMPv2-SMI
    DisplayString
        FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF;

kymataAmp MODULE-IDENTITY
    LAST-UPDATED "202607020000Z"
    ORGANIZATION "Guglielmo S.r.l."
    CONTACT-INFO
        "info@guglielmo.biz"
    DESCRIPTION
        "MIB for the Kymata AMPxx Amplifier.

        Kymata does not offer a MIB for this product.
        This MIB was created based on PDF documentation.
      
        MIB author:

        CTNET BV
        Rudy Broersma <r.broersma@ctnet.nl>
        Meerweg 143
        9752 XA Haren
        The Netherlands"
    REVISION "202607020000Z"
    DESCRIPTION
        "Initial release."
    ::= { enterprises 60429 }

family          OBJECT IDENTIFIER ::= { kymataAmp 1 }
productInfo     OBJECT IDENTIFIER ::= { family 1 }
snmpInfo        OBJECT IDENTIFIER ::= { family 2 }
hardwareData    OBJECT IDENTIFIER ::= { family 3 }
softwareInfo    OBJECT IDENTIFIER ::= { family 4 }
networkData     OBJECT IDENTIFIER ::= { family 5 }

factoryData     OBJECT IDENTIFIER ::= { networkData 1 }
userData        OBJECT IDENTIFIER ::= { networkData 2 }
identification  OBJECT IDENTIFIER ::= { snmpInfo 1 }
trapConfig      OBJECT IDENTIFIER ::= { snmpInfo 2 }
dns             OBJECT IDENTIFIER ::= { userData 5 }

productName OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Product name."
    ::= { productInfo 1 }

hwVersion OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Hardware version."
    ::= { productInfo 2 }

hwReleaseDate OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Hardware release date (YYYYMM). Agent returns Integer32."
    ::= { productInfo 3 }

serialNumber OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    ::= { productInfo 4 }

fwVersion OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    ::= { productInfo 5 }

lot OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    ::= { productInfo 6 }

groupGatewayId OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    ::= { identification 1 }

gatewayLabel OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Documentation indicates string; firmware returns Integer32."
    ::= { identification 2 }

trapReceiverNumber OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    ::= { trapConfig 1 }

trapEnabled OBJECT-TYPE
    SYNTAX INTEGER { disabled(0), enabled(1) }
    MAX-ACCESS read-write
    STATUS current
    ::= { trapConfig 2 }

trapReceiverIPAddress OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS read-write
    STATUS current
    ::= { trapConfig 3 }

trapCommunity OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-write
    STATUS current
    ::= { trapConfig 4 }

alarmStatus OBJECT-TYPE
    SYNTAX INTEGER {
        noAlarm(0),
        apAlarm(1),
        lowOutputPower(2),
        pcbPowerFault(3),
        highTemperature(4)
    }
    MAX-ACCESS read-only
    STATUS current
    ::= { hardwareData 1 }

temperature OBJECT-TYPE
    SYNTAX Integer32
    UNITS "degrees Celsius"
    MAX-ACCESS read-only
    STATUS current
    ::= { hardwareData 10 }

voltage5V OBJECT-TYPE
    SYNTAX Integer32
    UNITS "millivolts"
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Example value 3741 = 3.741V."
    ::= { hardwareData 11 }

rfOut OBJECT-TYPE
    SYNTAX Integer32
    UNITS "0.01 dBm"
    MAX-ACCESS read-only
    STATUS current
    ::= { hardwareData 12 }

errorSeconds OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    ::= { hardwareData 13 }

packetCounter OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Packets per minute"
    ::= { hardwareData 14 }

activityAP OBJECT-TYPE
    SYNTAX INTEGER { off(0), beacon(1), traffic(2) }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "AP Activity"
    ::= { hardwareData 15 }

pcbPowerProblem OBJECT-TYPE
    SYNTAX INTEGER { absent(0), present(1) }
    MAX-ACCESS read-only
    STATUS current
    ::= { hardwareData 16 }

macAddress OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    ::= { factoryData 1 }

defaultIPAddress OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS read-only
    STATUS current
    ::= { factoryData 2 }

defaultNetmask OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS read-only
    STATUS current
    ::= { factoryData 3 }

hostName OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-write
    STATUS current
    ::= { userData 1 }

ipAddress OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS read-write
    STATUS current
    ::= { userData 2 }

netmask OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS read-write
    STATUS current
    ::= { userData 3 }

gateway OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS read-write
    STATUS current
    ::= { userData 4 }

dns1 OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS read-write
    STATUS current
    ::= { dns 1 }

dns2 OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS read-write
    STATUS current
    ::= { dns 2 }

ntpServer OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-write
    STATUS current
    ::= { userData 6 }

snmpServer OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS read-write
    STATUS current
    ::= { userData 7 }

kymataObjects OBJECT-GROUP
    OBJECTS {
        productName, hwVersion, hwReleaseDate, serialNumber,
        fwVersion, lot, groupGatewayId, gatewayLabel,
        trapReceiverNumber, trapEnabled, trapReceiverIPAddress,
        trapCommunity, alarmStatus, temperature, voltage5V,
        rfOut, errorSeconds, packetCounter, activityAP,
        pcbPowerProblem, macAddress, defaultIPAddress, defaultNetmask,
        hostName, ipAddress, netmask, gateway,
        dns1, dns2, ntpServer, snmpServer
    }
    STATUS current
    DESCRIPTION "Collection of Amp managed objects."
    ::= { kymataAmp 2 }

kymataCompliance MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION "Compliance statement."
    MODULE
        MANDATORY-GROUPS { kymataObjects }
    ::= { kymataAmp 3 }

END